smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-8-amd64] (local build) Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: KINGSTON SA400S37480G Serial Number: 50026B7682DEDB7B LU WWN Device Id: 5 0026b7 682dedb7b Firmware Version: SBFKB1D1 User Capacity: 480,103,981,056 bytes [480 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-4 (minor revision not indicated) SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Feb 14 23:34:50 2020 -04 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART Status not supported: Incomplete response, ATA output registers missing SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (65535) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0032 000 100 000 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 3772 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 8 148 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 149 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0 169 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 16 170 Unknown_Attribute 0x0000 100 100 010 Old_age Offline - 11 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 173 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 3080266 181 Program_Fail_Cnt_Total 0x0032 100 100 000 Old_age Always - 0 182 Erase_Fail_Count_Total 0x0000 100 100 000 Old_age Offline - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 7 194 Temperature_Celsius 0x0022 076 069 000 Old_age Always - 24 (Min/Max 20/31) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0 218 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 231 Temperature_Celsius 0x0000 005 005 000 Old_age Offline - 95 233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 10708 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 3119 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 1353 244 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 47 245 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 74 246 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 737312 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.